Waste anesthetic gas in veterinary clinics: exposure and control

Every inhalant anesthetic leaves a little gas in the room, and the people who breathe it are the technicians, nurses, veterinarians and students who work there every day.

Brown glass bottle of an early anesthetic

The student holds the mask over the cat’s face, the cat turns its head, the seal breaks, and for a second there is that faint, sweet, slightly ether-like smell in the air. Nobody in the room comments on it. It happens a dozen times a week in a busy clinic, and that is exactly why it deserves attention.

Waste anesthetic gases, usually shortened to WAG, are the small amounts of inhalant anesthetic that escape from the breathing system into the room instead of reaching the patient or the scavenger. In most veterinary practices today that means isoflurane or sevoflurane, sometimes with nitrous oxide; older agents such as halothane are rarely used now. If you work with these agents daily, what follows is about your own breathing zone, not the patient’s.

Where exposure happens

Most exposure comes from a short list of routine moments rather than from dramatic failures. Some are built into the way anesthesia is delivered, and some are simple mistakes that become habits.

  • Mask and chamber induction. Gas escapes around the mask edge and floods out when the chamber is opened. This is the single largest source in many clinics.
  • Uncuffed or under-inflated endotracheal tubes. Gas leaks around the tube on every breath, especially when the lungs are ventilated by squeezing the bag.
  • Turning the vaporizer on before the patient is connected, or leaving it on when the patient is disconnected for a move.
  • Disconnecting the circuit while it is still full of anesthetic, at the end of the procedure or to reposition the patient.
  • Machine leaks at worn O-rings, loose CO2 absorbent canisters, cracked hoses, perished reservoir bags and badly seated vaporizers.
  • Recovering patients exhaling anesthetic into the recovery area for some time after the vaporizer is switched off.
  • Filling vaporizers, especially with open-pour bottles, and spills.

The recovery ward is the one teams forget. A large dog breathing out isoflurane in a small kennel room can add noticeably to the air levels, and the people working there are often not the people who ran the anesthetic.

What NIOSH and OSHA say about the health effects

Two United States agencies set the reference points here. The National Institute for Occupational Safety and Health (NIOSH) publishes recommended exposure limits and guidance, including its booklet on waste anesthetic gases as an occupational hazard in hospitals. The Occupational Safety and Health Administration (OSHA) has published guidelines for workplace exposure to anesthetic gases but has not set a specific enforceable exposure limit for the halogenated agents.

NIOSH’s recommended limits date from its 1970s criteria document: 2 parts per million as a ceiling over a sampling period of up to one hour for halogenated agents, and 25 parts per million as a time-weighted average for nitrous oxide during the period of administration. Those figures were set at a time when halothane and other older agents were in use, and they are still the figures quoted today.

On health effects, the language from both agencies is careful, and it should stay careful when it is repeated. Short-term exposure to higher concentrations is associated with headache, fatigue, irritability, nausea, drowsiness and difficulty with judgment and coordination. For long-term exposure, NIOSH notes that studies have suggested links with liver and kidney disease and with reproductive problems, while the evidence is not conclusive. The cautious reading is the right one: the uncertainty is a reason to keep exposure as low as reasonably possible, not a reason to ignore it.

The smell is a warning in itself. The level at which most people can smell these agents is generally well above the NIOSH limit, so if a room smells of anesthetic, the air concentration is almost certainly higher than it should be.

Scavenging: active and passive

A scavenging system collects the gas leaving the breathing system and carries it out of the room. Active systems use a fan or a central vacuum to draw gas away, with an interface that stops the suction from pulling on the patient’s lungs. They work well when they are switched on, connected and running at the right flow, which sounds obvious until someone finds a scavenger hose lying on the floor behind the machine.

A scavenger protects nobody unless it is switched on, connected and looked after, which makes it a habit before it is a piece of equipment.

Passive systems rely on the patient’s own breathing, or the pressure in the circuit, to push gas through tubing to an outside vent or into an activated charcoal canister. Charcoal canisters absorb halogenated agents but not nitrous oxide, and they stop working once saturated, so they are weighed and replaced on schedule. Active scavenging is the better choice for a busy theater; passive systems are a reasonable answer where active scavenging is impractical, provided they are maintained.

Habits that cut exposure

Technique matters as much as equipment, and most of it costs nothing.

Leak-test the machine and breathing system before use. Choose an injectable induction followed by intubation with a cuffed tube whenever the patient’s condition allows, and save mask or chamber induction for the cases that genuinely need it. Inflate the cuff until the leak around it just stops when the bag is gently squeezed, without over-inflating it, since an over-inflated cuff can injure the trachea, a risk that is particularly well recognized in cats.

Turn the vaporizer on only after the patient is connected to the circuit. At the end of the procedure, switch the vaporizer off, keep the patient on oxygen and connected for a few minutes, and empty the reservoir bag into the scavenger before disconnecting. Do the same before any move from table to table. Fill vaporizers with a keyed filling system where the vaporizer allows it, at a quiet time, away from patients and colleagues, and close the bottle straight away.

Then there is the room itself. Good general ventilation in theaters and recovery areas dilutes whatever escapes, and recovering patients are better placed in a ventilated space than in a closed closet of a room. The patient’s side of the same period is the job of anesthesia monitoring.

Measuring what people actually breathe

Assumptions about exposure are often wrong in both directions. The simplest measurement is a passive dosimeter badge, clipped near the collar in the breathing zone and worn for a set period, typically a shift or a specific procedure, then sent to a laboratory for analysis. Badges can be worn by the anesthetist, the surgeon, the recovery nurse and the person who fills the vaporizers, which shows very quickly where the problem sits. Portable infrared analyzers, held by a trained person, can find individual leaks in real time.

Many clinics badge staff once or twice a year and again whenever the equipment or the layout changes. A result above the NIOSH figure is a prompt to look at technique and equipment, not a reason for alarm.

Pregnancy and waste anesthetic gases

This is the question staff ask most often, and it is the one where the evidence is least settled. Some studies, mostly older ones and mostly from human operating rooms, reported higher rates of miscarriage among exposed workers; others did not, and many of the older studies were done before scavenging was common. NIOSH lists reproductive effects among the possible concerns while describing the evidence as inconclusive.

In practice, many clinics allow pregnant staff to step back from mask and chamber inductions, vaporizer filling and recovery duties, and some arrange alternative work for the duration. The decision belongs to the employee, her doctor and the employer, guided by national rules, and a clinic with good scavenging and badge results already in its records is in a much better position to have that conversation.

For students, the reason these agents behave as they do in the body sits in how anesthesia works, and the specialists who teach most of this, and often write their hospital’s safety protocols, are profiled under the veterinary anesthesiologist. The next badge result is the useful thing to look at: who was wearing it, on what day, and which job they were doing.

Frequently asked questions

Who in a clinic should be responsible for waste gas control?

The employer carries the overall responsibility under workplace safety rules, but day-to-day control works best when one named person owns it: checking the scavenger, keeping the leak-test log, arranging badge testing and booking machine servicing. In larger hospitals that is often an anesthesia technician or the anesthesia service. Everyone who uses the machine still shares the habits that keep exposure low.

Is sevoflurane safer for staff than isoflurane?

Both are halogenated agents, and NIOSH guidance on waste anesthetic gases applies to them as a group. Sevoflurane is often used for mask induction because it is less irritating to breathe, which can make induction smoother, but it does not remove the exposure that mask induction causes. The controls that reduce exposure are the same for both agents.

How often should the anesthetic machine be leak-tested?

Common practice is a low-pressure leak test of the breathing system before every anesthetic, or at least at the start of each day, plus regular servicing of the machine and vaporizers by a qualified technician. Many clinics keep a written log. The manufacturer's instructions and the clinic's own safety policy set the exact schedule, and they should be followed where they differ from general advice.

Does a surgical face mask protect staff from waste anesthetic gas?

No. Surgical masks are designed to catch droplets and particles, and anesthetic vapors pass straight through them. They have a place in theater for infection control, but they do nothing for gas exposure. Protection comes from the measures that keep gas out of the breathing zone in the first place: working scavenging, a leak-tested machine, cuffed tubes, careful technique at connection and disconnection, and good ventilation in theater and recovery.

Sources and further reading

Explore the original publications behind this guide.

Keep reading

  1. Anesthesia monitor showing a heart trace

    Monitoring every vital sign

    ECG, pulse oximetry, CO2, blood pressure and temperature, the depth signs no machine shows, and what the paper record catches.